Low Pressure

£705.00
LP22-8040 Flow Rate - 1,650 L/h
Ref. RO4037
Description LP22-8040 Model
Permeated 1,650 L/h
Operating limit and conditions:
  • Permeate may vary about 20%.
  • Max. working pressure: 600 psi (4.14 Mpa)
  • Max. feedwater SDI: 5
  • Residual chlorine concentration: <0.1 ppm
  • pH range of feedwater during continuous operation: 3-10
  • pH range of feedwater during chemical cleaning: 2-12
  • Max. pressure drop of membrane: 15 psi (0.10 Mpa)
Availability :
Out of Stock [Delivery : 10 - 21 Days, ]
Qty :
Download PDF

Test Conditions:

  • Testing pressure: 225 psi (1,55 Mpa)
  • NaCI concentrated: 2000 ppm
  • Temperature of testing solutions: 25ºC
  • pH value of testing solution: 7.5
  • Recovery rate of membrane: 15%

RO4037

Permeated 39.70 m3/d
Max. feedwater flow 75 GPM (17 m3/h)
Minimum rejection rate 99.3%
Stable rejection rate 99.5%
Membrane area 37 m2